Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Biosens Bioelectron ; 257: 116292, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38653014

RESUMEN

We report the development and initial validation of a paper-based nucleic acid testing platform that integrates Loop-mediated isothermal amplification (LAMP) with clustered regularly interspaced short palindromic repeats (CRISPR) technology, referred to as PLACID (Paper-based LAMP-CRISPR Integrated Diagnostics). LAMP eliminates the need for thermal cycling, resulting in simplified instrumentation, and the CRISPR-associated protein (Cas 12a) system eliminates false positive signals from LAMP products, resulting in highly selective and sensitive assays. We optimized the assay to perform both amplification and detection entirely on paper, eliminating the need for complex fluid handling steps and lateral flow assay transfers. Additionally, we engineered a smartphone-operated system that includes a low-powered, non-contact IR heating chamber to actuate paper-based LAMP and CRISPR reactions and enable the detection of fluorescent signals from the paper. The platform demonstrates high specificity and sensitivity in detecting nucleic acid targets with a limit of detection of 50 copies/µL. We integrate an equipment-free sample preparation separation technology designed to streamline the preparation of crude samples prior to nucleic acid testing. The practical utility of our platform is demonstrated by the successful detection of spiked SARS-CoV-2 RNA fragments in saliva, E. Coli in soil, and pathogenic E. Coli in clinically fecal samples of infected patients. Furthermore, we demonstrate that the paper-based LAMP CRISPR chips employed in our assays possess a shelf life of several weeks, establishing them as viable candidates for on-site diagnostics.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Sistemas CRISPR-Cas , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Papel , SARS-CoV-2 , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Humanos , Técnicas Biosensibles/métodos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , COVID-19/diagnóstico , COVID-19/virología , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentación , Sistemas CRISPR-Cas/genética , Límite de Detección , Repeticiones Palindrómicas Cortas Agrupadas y Regularmente Espaciadas/genética , Diseño de Equipo , Prueba de Ácido Nucleico para COVID-19/métodos , Prueba de Ácido Nucleico para COVID-19/instrumentación , Escherichia coli/genética , Escherichia coli/aislamiento & purificación , Proteínas Asociadas a CRISPR/genética , Teléfono Inteligente
2.
Sci Rep ; 12(1): 3775, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35260588

RESUMEN

Loop-mediated isothermal amplification is known for its high sensitivity, specificity and tolerance to inhibiting-substances. In this work, we developed a device for performing real-time colorimetric LAMP combining the accuracy of lab-based quantitative analysis with the simplicity of point-of-care testing. The device innovation lies on the use of a plastic tube anchored vertically on a hot surface while the side walls are exposed to a mini camera able to take snapshots of the colour change in real time during LAMP amplification. Competitive features are the rapid analysis (< 30 min), quantification over 9 log-units, crude sample-compatibility (saliva, tissue, swabs), low detection limit (< 5 copies/reaction), smartphone-operation, fast prototyping (3D-printing) and ability to select the dye of interest (Phenol red, HNB). The device's clinical utility is demonstrated in cancer mutations-analysis during the detection of 0.01% of BRAF-V600E-to-wild-type molecules from tissue samples and COVID-19 testing with 97% (Ct < 36.8) and 98% (Ct < 30) sensitivity when using extracted RNA and nasopharyngeal-swabs, respectively. The device high technology-readiness-level makes it a suitable platform for performing any colorimetric LAMP assay; moreover, its simple and inexpensive fabrication holds promise for fast deployment and application in global diagnostics.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Colorimetría , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular , Nasofaringe/virología , Neoplasias/diagnóstico , Neoplasias/genética , Neoplasias/patología , Técnicas de Amplificación de Ácido Nucleico , Pruebas en el Punto de Atención , Proteínas Proto-Oncogénicas B-raf/genética , ARN Viral/análisis , ARN Viral/metabolismo , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Teléfono Inteligente
3.
Sci Rep ; 12(1): 3951, 2022 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-35273232

RESUMEN

The SARS-CoV-2 pandemic has brought to light the need for expedient diagnostic testing. Cost and availability of large-scale testing capacity has led to a lag in turnaround time and hindered contact tracing efforts, resulting in a further spread of SARS-CoV-2. To increase the speed and frequency of testing, we developed a cost-effective single-tube approach for collection, denaturation, and analysis of clinical samples. The approach utilizes 1 µL microbiological inoculation loops to collect saliva, sodium dodecyl sulfate (SDS) to inactivate and release viral genomic RNA, and a diagnostic reaction mix containing polysorbate 80 (Tween 80). In the same tube, the SDS-denatured clinical samples are introduced to the mixtures containing all components for nucleic acids detection and Tween 80 micelles to absorb the SDS and allow enzymatic reactions to proceed, obviating the need for further handling of the samples. The samples can be collected by the tested individuals, further decreasing the need for trained personnel to administer the test. We validated this single-tube sample-to-assay method with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) and reverse transcription loop-mediated isothermal amplification (RT-LAMP) and discovered little-to-no difference between Tween- and SDS-containing reaction mixtures, compared to control reactions. This approach reduces the logistical burden of traditional large-scale testing and provides a method of deployable point-of-care diagnostics to increase testing frequency.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , SARS-CoV-2/genética , Saliva/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Reacción en Cadena en Tiempo Real de la Polimerasa , Manejo de Especímenes/instrumentación , Manejo de Especímenes/métodos
4.
J Mater Sci Mater Med ; 33(1): 8, 2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-34982267

RESUMEN

The collection capacity of common nasopharyngeal swabs and irregularities of medical personnel limit the accuracy of PCR testing. This study describes a newly designed 3D-printed swab that is combined with a 3D-printed cover to prevent the extraction of undesired nasal secretions. This swab improved the accuracy of PCR test results. The results of a series of experiments showed that, because of the mucus extraction effect, 3D-printed swabs can replace ordinary cotton swabs. The crisis of the worldwide medical supply shortage can be ameliorated to a certain extent by applying 3D printing technology.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , Manejo de Especímenes/instrumentación , Materiales Biocompatibles , Fenómenos Biomecánicos , COVID-19/diagnóstico , COVID-19/virología , Simulación por Computador , Diseño de Equipo , Análisis de Elementos Finitos , Humanos , Ensayo de Materiales , Nasofaringe/virología , Impresión Tridimensional , Resinas Sintéticas , Seguridad , Resistencia a la Tracción , Textiles
5.
Bioprocess Biosyst Eng ; 45(3): 503-514, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35031864

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has had severe consequences for health and the global economy. To control the transmission, there is an urgent demand for early diagnosis and treatment in the general population. In the present study, an automatic system for SARS-CoV-2 diagnosis is designed and built to deliver high specification, high sensitivity, and high throughput with minimal workforce involvement. The system, set up with cross-priming amplification (CPA) rather than conventional reverse transcription-polymerase chain reaction (RT-PCR), was evaluated using more than 1000 real-world samples for direct comparison. This fully automated robotic system performed SARS-CoV-2 nucleic acid-based diagnosis with 192 samples in under 180 min at 100 copies per reaction in a "specimen in data out" manner. This throughput translates to a daily screening capacity of 800-1000 in an assembly-line manner with limited workforce involvement. The sensitivity of this device could be further improved using a CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats)-based assay, which opens the door to mixed samples, potentially include SARS-CoV-2 variants screening in extensively scaled testing for fighting COVID-19.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2 , Algoritmos , Ingeniería Biomédica/instrumentación , Ingeniería Biomédica/métodos , Ingeniería Biomédica/estadística & datos numéricos , COVID-19/epidemiología , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Repeticiones Palindrómicas Cortas Agrupadas y Regularmente Espaciadas , Diseño de Equipo , Ensayos Analíticos de Alto Rendimiento/instrumentación , Ensayos Analíticos de Alto Rendimiento/métodos , Ensayos Analíticos de Alto Rendimiento/estadística & datos numéricos , Humanos , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas de Amplificación de Ácido Nucleico/estadística & datos numéricos , Pandemias , Robótica/instrumentación , Robótica/métodos , Robótica/estadística & datos numéricos , SARS-CoV-2/genética , Sensibilidad y Especificidad , Análisis de Sistemas
6.
Anal Biochem ; 641: 114565, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35074320

RESUMEN

Polymerase chain reaction (PCR) is the most widely used method for nucleic acids amplification. To date, a huge number of versatile PCR techniques have been developed. One of the relevant goals is to shorten PCR duration, which can be achieved in several ways. Here, we report on the results regarding nucleic acids amplification by convective PCR (cPCR) in standard 0.2 ml polypropylene microtubes. The following conditions were found to be optimal for such amplification: 1) 70 µl reaction volume, 2) the supply of external temperature 145°Ð¡ for the denaturation zone and 0°Ð¡ for the annealing zone, 3) ∼30° inclination of the microtube main axis, 4) the use of nearby primers, and 5) duration of the reaction 15-20 min. At these conditions, the amplification products are accumulated in an amount sufficient to be registered by gel electrophoresis, and high sensitivity of the reaction comparable to that of conventional PCR is achieved. cPCR provided the reliable detection of SARS-CoV-2 coronavirus RNA isolated from nasopharyngeal swabs of COVID-19 patients.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Reacción en Cadena de la Polimerasa/instrumentación , SARS-CoV-2/aislamiento & purificación , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/economía , Prueba de Ácido Nucleico para COVID-19/métodos , Convección , Humanos , Reacción en Cadena de la Polimerasa/economía , Reacción en Cadena de la Polimerasa/métodos , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2/genética , Temperatura , Factores de Tiempo
7.
PLoS One ; 16(9): e0257464, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34529736

RESUMEN

Despite the development of effective vaccines against SARS-CoV-2, epidemiological control of the virus is still challenging due to slow vaccine rollouts, incomplete vaccine protection to current and emerging variants, and unwillingness to get vaccinated. Therefore, frequent testing of individuals to identify early SARS-CoV-2 infections, contact-tracing and isolation strategies remain crucial to mitigate viral spread. Here, we describe WHotLAMP, a rapid molecular test to detect SARS-CoV-2 in saliva. WHotLAMP is simple to use, highly sensitive (~4 viral particles per microliter of saliva) and specific, as well as inexpensive, making it ideal for frequent screening. Moreover, WHotLAMP does not require toxic chemicals or specialized equipment and thus can be performed in point-of-care settings, and may also be adapted for resource-limited environments or home use. While applied here to SARS-CoV-2, WHotLAMP can be modified to detect other pathogens, making it adaptable for other diagnostic assays, including for use in future outbreaks.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , ARN Viral/genética , SARS-CoV-2/genética , Saliva/virología , COVID-19/epidemiología , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Epidemias/prevención & control , Humanos , Sistemas de Atención de Punto/estadística & datos numéricos , ARN Viral/aislamiento & purificación , Reproducibilidad de los Resultados , SARS-CoV-2/fisiología , Sensibilidad y Especificidad
8.
Mol Biol Rep ; 48(10): 6871-6877, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34510319

RESUMEN

BACKGROUND: RT-qPCR technique is the current world-wide method used for the early detection of SARS-CoV2 RNA in the suspected clinical samples. Viral RNA extraction is the key pre-analytical step for SARS-CoV2 detection which often achieved using commercial RNA-extraction kits. However, due to the COVID-19 pandemic, bulk production and the supply chains for the commercial RNA-extraction kit have been seriously compromised. The shortage of commercial RNA-extraction kit is even more acute in developing country. Furthermore, use of one-off design RNA-columns can generate plastic wastes that have an environmental pollution effect. METHODS AND RESULTS: To address these issues, in this study, we used warm alkaline solution containing Triton X-100 for the complete removal of the residual SARS-CoV2 RNA from the used RNA-binding silica column. Columns regenerated using the alkaline solution have the viral RNA purification capability that is comparable to the fresh silica columns. We also demonstrated that RNA-binding silica columns can be regenerated and reused for a minimum of five-times. CONCLUSIONS: Therefore, the use of the RNA-column regeneration method may benefits several SARS-CoV2 diagnostic laboratories throughout the world by cutting down the requirement of commercial RNA-purification column.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , Cromatografía/instrumentación , ARN Viral/aislamiento & purificación , Prueba de Ácido Nucleico para COVID-19/métodos , Cromatografía/métodos , Humanos , Octoxinol , ARN Viral/metabolismo , Reacción en Cadena en Tiempo Real de la Polimerasa , Reciclaje , Dióxido de Silicio
10.
Sci Rep ; 11(1): 15997, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-34362977

RESUMEN

Simple tests of infectiousness that return results in minutes and directly from samples even with low viral loads could be a potential game-changer in the fight against COVID-19. Here, we describe an improved isothermal nucleic acid amplification assay, termed the RICCA (RNA Isothermal Co-assisted and Coupled Amplification) reaction, that consists of a simple one-pot format of 'sample-in and result-out' with a primary focus on the detection of low copy numbers of RNA virus directly from saliva without the need for laboratory processing. We demonstrate our assay by detecting 16S rRNA directly from E. coli cells with a sensitivity as low as 8 CFU/µL and RNA fragments from a synthetic template of SARS-CoV-2 with a sensitivity as low as 1740 copies/µL. We further demonstrate the applicability of our assay for real-time testing at the point of care by designing a closed format for paper-based lateral flow assay and detecting heat-inactivated SARS-COV-2 virus in human saliva at concentrations ranging from 28,000 to 2.8 copies/µL with a total assay time of 15-30 min.


Asunto(s)
COVID-19/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , Sistemas de Atención de Punto , Virus ARN/genética , ARN Viral/genética , SARS-CoV-2/genética , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Prueba de Ácido Nucleico para COVID-19/métodos , Diseño de Equipo , Humanos , Límite de Detección , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Virus ARN/aislamiento & purificación , ARN Viral/análisis , SARS-CoV-2/aislamiento & purificación , Saliva/virología
11.
Sci Rep ; 11(1): 15869, 2021 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-34354202

RESUMEN

Since December 2019, a novel coronavirus responsible for a severe acute respiratory syndrome (SARS-CoV-2) is accountable for a major pandemic situation. The emergence of the B.1.1.7 strain, as a highly transmissible variant has accelerated the world-wide interest in tracking SARS-CoV-2 variants' occurrence. Similarly, other extremely infectious variants, were described and further others are expected to be discovered due to the long period of time on which the pandemic situation is lasting. All described SARS-CoV-2 variants present several mutations within the gene encoding the Spike protein, involved in host receptor recognition and entry into the cell. Hence, instead of sequencing the whole viral genome for variants' tracking, herein we propose to focus on the SPIKE region to increase the number of candidate samples to screen at once; an essential aspect to accelerate diagnostics, but also variants' emergence/progression surveillance. This proof of concept study accomplishes both at once, population-scale diagnostics and variants' tracking. This strategy relies on (1) the use of the portable MinION DNA sequencer; (2) a DNA barcoding and a SPIKE gene-centered variant's tracking, increasing the number of candidates per assay; and (3) a real-time diagnostics and variant's tracking monitoring thanks to our software RETIVAD. This strategy represents an optimal solution for addressing the current needs on SARS-CoV-2 progression surveillance, notably due to its affordable implementation, allowing its implantation even in remote places over the world.


Asunto(s)
COVID-19/diagnóstico , SARS-CoV-2/genética , Análisis de Secuencia de ADN/métodos , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Prueba de Ácido Nucleico para COVID-19/métodos , Genoma Viral , Humanos , Nanoporos , ARN Viral/genética , Análisis de Secuencia de ADN/instrumentación , Glicoproteína de la Espiga del Coronavirus/genética
12.
PLoS One ; 16(8): e0256316, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34407126

RESUMEN

Efficient and effective viral detection methodologies are a critical piece in the global response to COVID-19, with PCR-based nasopharyngeal and oropharyngeal swab testing serving as the current gold standard. With over 100 million confirmed cases globally, the supply chains supporting these PCR testing efforts are under a tremendous amount of stress, driving the need for innovative and accurate diagnostic solutions. Herein, the utility of a direct-to-PCR method of SARS-CoV-2 detection grounded in mechanical homogenization is examined for reducing resources needed for testing while maintaining a comparable sensitivity to the current gold standard workflow of nasopharyngeal and oropharyngeal swab testing. In a head-to-head comparison of 30 patient samples, this initial clinical validation study of the proposed homogenization-based workflow demonstrated significant agreeability with the current extraction-based method utilized while cutting the total resources needed in half.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Manejo de Especímenes/instrumentación , Prueba de Ácido Nucleico para COVID-19/instrumentación , Estudios de Factibilidad , Humanos , Nasofaringe/virología , Orofaringe/virología , Estudios Prospectivos , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2/genética , Sensibilidad y Especificidad , Flujo de Trabajo
13.
Eur J Clin Microbiol Infect Dis ; 40(12): 2489-2496, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34224033

RESUMEN

Easy access to screening for timely identification and isolation of infectious COVID-19 patients remains crucial in sustaining the international efforts to control COVID-19 spread. A major barrier limiting broad-based screening is the lack of a simple, rapid, and cost-effective COVID-19 testing method. We evaluated the feasibility and utility of facemask sampling in a cohort of 42 COVID-19-positive and 36 COVID-19-negative patients. We used a prototype of Steri-Strips™ (3 M) applied to the inner surface of looped surgical facemasks (Assure), which was worn by patients for a minimum wear time of 3 h, then removed and sent for SARS-CoV-2 PCR testing. Baseline demographics and symptomatology were also collected. Facemask sampling positivity was highest within the first 5 days of symptomatic presentation. Patients with nasopharyngeal and/or oropharyngeal swab SARS-CoV-2 PCR Ct values < 25.09 had SARS-CoV-2 detected on facemask sampling, while patients with Ct values ≥ 25.2 had no SARS-CoV-2 detected on facemask sampling. Facemask sampling can identify patients with COVID-19 during the early symptomatic phase or those with high viral loads, hence allowing timely identification and isolation of those with the highest transmission risk. Given the widespread use of facemasks, this method can potentially be easily applied to achieve broad-based, or even continuous, population screening.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/virología , Máscaras/virología , SARS-CoV-2/aislamiento & purificación , Adulto , Anciano , COVID-19/diagnóstico , COVID-19/epidemiología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Orofaringe/virología , Pandemias , SARS-CoV-2/clasificación , SARS-CoV-2/genética , Adulto Joven
14.
Arch Virol ; 166(9): 2529-2540, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34251549

RESUMEN

RT-qPCR detection of SARS-CoV-2 RNA still represents the method of reference to diagnose and monitor COVID-19. From the onset of the pandemic, however, doubts have been expressed concerning the sensitivity of this molecular diagnosis method. Droplet digital PCR (ddPCR) is a third-generation PCR technique that is particularly adapted to detecting low-abundance targets. We developed two-color ddPCR assays for the detection of four different regions of SARS-CoV-2 RNA, including non-structural (IP4-RdRP, helicase) and structural (E, N) protein-encoding sequences. We observed that N or E subgenomic RNAs are generally more abundant than IP4 and helicase RNA sequences in cells infected in vitro, suggesting that detection of the N gene, coding for the most abundant subgenomic RNA of SARS-CoV-2, increases the sensitivity of detection during the highly replicative phase of infection. We investigated 208 nasopharyngeal swabs sampled in March-April 2020 in different hospitals of Greater Paris. We found that 8.6% of informative samples (n = 16/185, P < 0.0001) initially scored as "non-positive" (undetermined or negative) by RT-qPCR were positive for SARS-CoV-2 RNA by ddPCR. Our work confirms that the use of ddPCR modestly, but significantly, increases the proportion of upper airway samples testing positive in the framework of first-line diagnosis of a French population.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , ARN Viral/genética , SARS-CoV-2/genética , Proteínas Virales/genética , COVID-19/epidemiología , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Color , Proteínas de la Envoltura de Coronavirus/genética , Proteínas de la Nucleocápside de Coronavirus/genética , Francia/epidemiología , Expresión Génica , Humanos , Límite de Detección , Nasofaringe/virología , Fosfoproteínas/genética , ARN Helicasas/genética , ARN Polimerasa Dependiente del ARN/genética , Carga Viral
15.
Nat Commun ; 12(1): 4317, 2021 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-34262053

RESUMEN

The COVID-19 pandemic exposed difficulties in scaling current quantitative PCR (qPCR)-based diagnostic methodologies for large-scale infectious disease testing. Bottlenecks include lengthy multi-step processes for nucleic acid extraction followed by qPCR readouts, which require costly instrumentation and infrastructure, as well as reagent and plastic consumable shortages stemming from supply chain constraints. Here we report an Oil Immersed Lossless Total Analysis System (OIL-TAS), which integrates RNA extraction and detection onto a single device that is simple, rapid, cost effective, and requires minimal supplies and infrastructure to perform. We validated the performance of OIL-TAS using contrived SARS-CoV-2 viral particle samples and clinical nasopharyngeal swab samples. OIL-TAS showed a 93% positive predictive agreement (n = 57) and 100% negative predictive agreement (n = 10) with clinical SARS-CoV-2 qPCR assays in testing clinical samples, highlighting its potential to be a faster, cheaper, and easier-to-deploy alternative for infectious disease testing.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Prueba de Ácido Nucleico para COVID-19/economía , Prueba de Ácido Nucleico para COVID-19/instrumentación , Diseño de Equipo , Humanos , Técnicas de Diagnóstico Molecular , Nasofaringe/virología , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/genética , ARN Viral/aislamiento & purificación , Reproducibilidad de los Resultados , SARS-CoV-2/genética , Sensibilidad y Especificidad , Factores de Tiempo , Virión/genética , Virión/aislamiento & purificación
16.
Arch Virol ; 166(9): 2551-2561, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34259914

RESUMEN

The aim of this study was to identify and validate a sensitive, high-throughput, and cost-effective SARS-CoV-2 real-time RT-PCR assay to be used as a surveillance and diagnostic tool for SARS-CoV-2 in a university surveillance program. We conducted a side-by-side clinical evaluation of a newly developed SARS-CoV-2 multiplex assay (EZ-SARS-CoV-2 Real-Time RT-PCR) with the commercial TaqPath COVID-19 Combo Kit, which has an Emergency Use Authorization from the FDA. The EZ-SARS-CoV-2 RT-PCR incorporates two assays targeting the SARS-CoV-2 N gene, an internal control targeting the human RNase P gene, and a PCR inhibition control in a single reaction. Nasopharyngeal (NP) and anterior nares (AN) swabs were tested as individuals and pools with both assays and in the ABI 7500 Fast and the QuantStudio 5 detection platforms. The analytical sensitivity of the EZ-SARS-CoV-2 RT-PCR assay was 250 copies/ml or approximately 1.75 genome copy equivalents per reaction. The clinical performance of the EZ-SARS-CoV-2 assay was evaluated using NP and AN samples tested in other laboratories. The diagnostic sensitivity of the assay ranged between 94 and 96% across the detection platforms, and the diagnostic specificity was 94.06%. The positive predictive value was 94%, and the negative predictive value ranged from 94 to 96%. Pooling five NP or AN specimens yielded 93% diagnostic sensitivity. The overall agreement between these SARS-CoV-2 RT-PCR assays was high, supported by a Cohen's kappa value of 0.93. The EZ-SARS-CoV-2 RT-PCR assay performance attributes of high sensitivity and specificity with AN sample matrix and pooled upper respiratory samples support its use in a high-throughput surveillance testing program.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Proteínas de la Nucleocápside de Coronavirus/genética , Reacción en Cadena de la Polimerasa Multiplex/métodos , ARN Viral/genética , SARS-CoV-2/genética , COVID-19/epidemiología , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/economía , Prueba de Ácido Nucleico para COVID-19/instrumentación , Monitoreo Epidemiológico , Expresión Génica , Humanos , Reacción en Cadena de la Polimerasa Multiplex/economía , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Cavidad Nasal/virología , Nasofaringe/virología , Fosfoproteínas/genética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Manejo de Especímenes/métodos , Carga Viral
17.
PLoS One ; 16(7): e0252509, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34260637

RESUMEN

The current global pandemic due to the SARS-CoV-2 has pushed the limits of global health systems across all aspects of clinical care, including laboratory diagnostics. Supply chain disruptions and rapidly-shifting markets have resulted in flash-scarcity of commercial laboratory reagents; this has motivated health care providers to search for alternative workflows to cope with the international increase in demand for SARS-CoV-2 testing. The aim of this study is to present a reproducible workflow for real time RT-PCR SARS-CoV-2 testing using OT-2 open-source liquid-handling robots (Opentrons, NY). We have developed a framework that includes a code template which is helpful for building different stand-alone robotic stations, capable of performing specific protocols. Such stations can be combined together to create a complex multi-stage workflow, from sample setup to real time RT-PCR. Using our open-source code, it is easy to create new stations or workflows from scratch, adapt existing templates to update the experimental protocols, or to fine-tune the code to fit specific needs. Using this framework, we developed the code for two different workflows and evaluated them using external quality assessment (EQA) samples from the European Molecular Genetics Quality Network (EMQN). The affordability of this platform makes automated SARS-CoV-2 PCR testing accessible for most laboratories and hospitals with qualified bioinformatics personnel. This platform also allows for flexibility, as it is not dependent on any specific commercial kit, and thus it can be quickly adapted to protocol changes, reagent, consumable shortages, or any other temporary material constraints.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , SARS-CoV-2/aislamiento & purificación , Codificación Clínica , Diagnóstico Precoz , Humanos , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Robótica , SARS-CoV-2/genética , Flujo de Trabajo
18.
Nat Commun ; 12(1): 4400, 2021 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-34285229

RESUMEN

Rapid and widespread testing of severe acute respiratory coronavirus 2 (SARS-CoV-2) is essential for an effective public health response aimed at containing and mitigating the coronavirus disease 2019 (COVID-19) pandemic. Successful health policy implementation relies on early identification of infected individuals and extensive contact tracing. However, rural communities, where resources for testing are sparse or simply absent, face distinctive challenges to achieving this success. Accordingly, we report the development of an academic, public land grant University laboratory-based detection assay for the identification of SARS-CoV-2 in samples from various clinical specimens that can be readily deployed in areas where access to testing is limited. The test, which is a quantitative reverse transcription polymerase chain reaction (RT-qPCR)-based procedure, was validated on samples provided by the state laboratory and submitted for FDA Emergency Use Authorization. Our test exhibits comparable sensitivity and exceeds specificity and inclusivity values compared to other molecular assays. Additionally, this test can be re-configured to meet supply chain shortages, modified for scale up demands, and is amenable to several clinical specimens. Test development also involved 3D engineering critical supplies and formulating a stable collection media that allowed samples to be transported for hours over a dispersed rural region without the need for a cold-chain. These two elements that were critical when shortages impacted testing and when personnel needed to reach areas that were geographically isolated from the testing center. Overall, using a robust, easy-to-adapt methodology, we show that an academic laboratory can supplement COVID-19 testing needs and help local health departments assess and manage outbreaks. This additional testing capacity is particularly germane for smaller cities and rural regions that would otherwise be unable to meet the testing demand.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Juego de Reactivos para Diagnóstico , Servicios de Salud Rural/organización & administración , COVID-19/epidemiología , COVID-19/prevención & control , COVID-19/virología , Control de Enfermedades Transmisibles/métodos , Control de Enfermedades Transmisibles/organización & administración , Diseño de Equipo , Humanos , Límite de Detección , Nasofaringe/virología , Pandemias/prevención & control , Impresión Tridimensional , ARN Viral/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Manejo de Especímenes/instrumentación , Manejo de Especímenes/métodos
19.
Sci Rep ; 11(1): 15176, 2021 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-34312441

RESUMEN

There is currently a high level of demand for rapid COVID-19 tests, that can detect the onset of the disease at point of care settings. We have developed an ultra-portable, self-contained, point-of-care nucleic acid amplification test for diagnosis of active COVID-19 infection, based on the principle of loop mediated isothermal amplification (LAMP). The LAMP assay is 100% sensitive and specific to detect a minimum of 300 RNA copies/reaction of SARS-CoV-2. All of the required sample transportation, lysing and amplification steps are performed in a standalone disposable cartridge, which is controlled by a battery operated, pocket size (6x9x4cm3) unit. The test is easy to operate and does not require skilled personnel. The total time from sample to answer is approximately 35 min; a colorimetric readout indicates positive or negative results. This portable diagnostic platform has significant potential for rapid and effective testing in community settings. This will accelerate clinical decision making, in terms of effective triage and timely therapeutic and infection control interventions.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Pruebas en el Punto de Atención , ARN Viral/genética , SARS-CoV-2/genética , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/economía , Diseño de Equipo , Humanos , Técnicas de Diagnóstico Molecular/economía , Técnicas de Amplificación de Ácido Nucleico/economía , Pruebas en el Punto de Atención/economía , ARN Viral/análisis , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Factores de Tiempo
20.
CRISPR J ; 4(3): 392-399, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34152219

RESUMEN

Rapid and clinically sensitive detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) play an important role in the contact tracing and containment of the COVID-19 pandemic. A recently developed field-deployable clustered regularly interspaced short palindromic repeats (CRISPR) detection assay with lateral flow strips shows promise for point-of-care detection of SARS-CoV-2. However, the limit of detection of paper strip-based assays (10-100 copies/µL) is much lower than that of fluorescence-based detection methods. In this study, we developed an easy-readout and sensitive enhanced (ERASE) strip to visualize the results of CRISPR detection and improve the sensitivity to 1 copy/µL with an unambiguous easy-read result. Using 649 clinical samples from blind specimens collected from patients in China, we validated our ERASE assay for SARS-CoV-2 RNA detection with 90.67% positive predictive agreement and 99.21% negative predictive agreement. In conclusion, our study provided a customized CRISPR strip for use in a simple, rapid, ultrasensitive, and highly specific assay for SARS-CoV-2 detection. (Clinical Trial Registration number: 2020-008-01; [2020]IEC(ZD01); PJ-NBEY-2020-009-01; 2020#34).


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Sistemas CRISPR-Cas/genética , Pruebas en el Punto de Atención , SARS-CoV-2/aislamiento & purificación , COVID-19/virología , Humanos , Límite de Detección , Valor Predictivo de las Pruebas , ARN Viral/genética , ARN Viral/aislamiento & purificación , Juego de Reactivos para Diagnóstico , SARS-CoV-2/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...